Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Biomed Opt Express ; 14(1): 299-314, 2023 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-36698677

RESUMO

Optical coherence tomography (OCT) and scanning laser ophthalmoscopy (SLO) are imaging technologies invented in the 1980s that have revolutionized the field of in vivo retinal diagnostics and are now commonly used in ophthalmology clinics as well as in vision science research. Adaptive optics (AO) technology enables high-fidelity correction of ocular aberrations, resulting in improved resolution and sensitivity for both SLO and OCT systems. The potential of gathering multi-modal cellular-resolution information in a single instrument is of great interest to the ophthalmic imaging community. Although similar instruments have been developed for imaging the human retina, developing such a system for mice will benefit basic science research and should help with further dissemination of AO technology. Here, we present our work integrating OCT into an existing mouse retinal AO-SLO system, resulting in a multi-modal AO-enhanced imaging system of the living mouse eye. The new system allows either independent or simultaneous data acquisition of AO-SLO and AO-OCT, depending on the requirements of specific scientific experiments. The system allows a data acquisition speed of 200 kHz A-scans/pixel rate for OCT and SLO, respectively. It offers ∼6 µm axial resolution for AO-OCT and a ∼1 µm lateral resolution for AO-SLO-OCT imaging.

2.
J Opt Soc Am A Opt Image Sci Vis ; 37(10): 1548-1556, 2020 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-33104604

RESUMO

Adaptive optics (AO) is an established technique to measure and compensate for optical aberrations. One of its key components is the wavefront sensor (WFS), which is typically a Shack-Hartmann sensor (SH) capturing an image related to the aberrated wavefront. We propose an efficient implementation of the SH-WFS centroid extraction algorithm, tailored for edge computing. In the edge-computing paradigm, the data are elaborated close to the source (i.e., at the edge) through low-power embedded architectures, in which CPU computing elements are combined with heterogeneous accelerators (e.g., GPUs, field-programmable gate arrays). Since the control loop latency must be minimized to compensate for the wavefront aberration temporal dynamics, we propose an optimized algorithm that takes advantage of the unified CPU/GPU memory of recent low-power embedded architectures. Experimental results show that the centroid extraction latency obtained over spot images up to 700×700 pixels wide is smaller than 2 ms. Therefore, our approach meets the temporal requirements of small- to medium-sized AO systems, which are equipped with deformable mirrors having tens of actuators.

3.
Biomed Opt Express ; 10(9): 4757-4774, 2019 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-31565523

RESUMO

Adaptive Optics (AO) is required to achieve diffraction limited resolution in many real-life imaging applications in biology and medicine. AO is essential to guarantee high fidelity visualization of cellular structures for retinal imaging by correcting ocular aberrations. Aberration correction for mouse retinal imaging by direct wavefront measurement has been demonstrated with great success. However, for mouse eyes, the performance of the wavefront sensor (WFS) based AO can be limited by several factors including non-common path errors, wavefront reconstruction errors, and an ill-defined reference plane. Image-based AO can avoid these issues at the cost of algorithmic execution time. Furthermore, image-based approaches can provide improvements to compactness, accessibility, and even the performance of AO systems. Here, we demonstrate the ability of image-based AO to provide comparable aberration correction and image resolution to the conventional Shack-Hartmann WFS-based AO approach. The residual wavefront error of the mouse eye was monitored during a wavefront sensorless optimization to allow comparison with classical AO. This also allowed us to improve the performance of our AO system for small animal retinal imaging.

4.
Opt Lett ; 44(3): 606-609, 2019 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-30702690

RESUMO

In free-space optical communication, the propagation of a laser beam through the atmosphere causes wavefront distortions that decrease the coupling efficiency (CE) from free space to single-mode fiber. This tremendously degrades the performance of the communication channel even in the case of weak turbulence regime. In this Letter, we demonstrate that a multi-actuator adaptive lens working in closed loop with a wavefront sensor can strongly reduce the effect of turbulence while reducing the system complexity with respect to correction systems using deformable mirrors or liquid crystal spatial light modulators. We obtain a three-fold increase in the CE in weak turbulence regime.

5.
Sci Rep ; 8(1): 14317, 2018 Sep 25.
Artigo em Inglês | MEDLINE | ID: mdl-30254247

RESUMO

The use of fast closed-loop adaptive optics has improved the performance of optical systems since its first application. Here we demonstrate the amplitude and carrier-envelope phase stabilization of a high energy IR optical parametric amplifier devoted to Attosecond Science exploiting two high speed adaptive optical systems for the correction of static and dynamic instabilities. The exploitation of multi actuator adaptive lenses allowed for a minimal impact on the optical setup.

6.
Exp Eye Res ; 172: 86-93, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29604280

RESUMO

For in vivo mouse retinal imaging, especially with Adaptive Optics instruments, application of a contact lens is desirable, as it allows maintenance of cornea hydration and helps to prevent cataract formation during lengthy imaging sessions. However, since the refractive elements of the eye (cornea and lens) serve as the objective for most in vivo retinal imaging systems, the use of a contact lens, even with 0 Dpt. refractive power, can alter the system's optical properties. In this investigation we examined the effective focal length change and the aberrations that arise from use of a contact lens. First, focal length changes were simulated with a Zemax mouse eye model. Then ocular aberrations with and without a 0 Dpt. contact lens were measured with a Shack-Hartmann wavefront sensor (SHWS) in a customized AO-SLO system. Total RMS wavefront errors were measured for two groups of mice (14-month, and 2.5-month-old), decomposed into 66 Zernike aberration terms, and compared. These data revealed that vertical coma and spherical aberrations were increased with use of a contact lens in our system. Based on the ocular wavefront data we evaluated the effect of the contact lens on the imaging system performance as a function of the pupil size. Both RMS error and Strehl ratios were quantified for the two groups of mice, with and without contact lenses, and for different input beam sizes. These results provide information for determining optimum pupil size for retinal imaging without adaptive optics, and raise critical issues for design of mouse optical imaging systems that incorporate contact lenses.


Assuntos
Lentes de Contato , Córnea/fisiopatologia , Aberrações de Frente de Onda da Córnea/fisiopatologia , Refração Ocular/fisiologia , Retina/diagnóstico por imagem , Aberrometria , Animais , Camundongos , Camundongos Endogâmicos C57BL , Oftalmoscópios , Pupila/fisiologia
7.
Opt Express ; 24(12): 13157-72, 2016 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-27410333

RESUMO

We explore adaptive optics (AO) pre-compensation for optical communication between Earth and geostationary (GEO) satellites in a laboratory experiment. Thus, we built a rapid control prototyping breadboard with an adjustable point-ahead angle where downlink and uplink can operate both at 1064 nm and 1550 nm wavelength. With our real-time system, beam wander resulting from artificial turbulence was reduced such that the beam hits the satellite at least 66% of the time as compared to merely 3% without correction. A seven-fold increase of the average Strehl ratio to (28 ± 15)% at 18 µrad point-ahead angle leads to a considerable reduction of the calculated fading probability. These results make AO pre-compensation a viable technique to enhance Earth-to-GEO optical communication.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...